Density Test Report
Date :03/18/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :03/18/2024 10:00
Onsite Hours :03:30
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :03/18/2024 13:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
03/18/2024 | 1 | 16.3 | 103.4 | 24469 | 103.9 | 18.7 | 99.5 | 90 | D6938 | Pass |
Location : | Lot #31, Elv/Depth :5.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
03/18/2024 | 2 | 15.7 | 102.5 | 24469 | 103.9 | 18.7 | 98.7 | 95 | D6938 | Pass |
Location : | Lot #31, Elv/Depth :5.5 below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, March 18, 2024
Reviewer Name / DateKenneth Mosman, March 28, 2024