Density Test Report

Date :02/28/2024
Project No :2022C165
Client Company :Toll Bros. Inc.
Arrival Time :02/28/2024 8:00
Onsite Hours :03:30
Name of the Project :Northfield @ Polo Fields - Phase2
Project Location :Pittman Road, Cumming, GA
Weather :sunny
Departure Time :02/28/2024 11:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/28/2024 1 24.5 86.5 1 83.2 25.3 104.0 95 D6938 Pass
Location : Lot #25, Elv/Depth :6 inches below finished grade
Comment : Gauge Serial No. :85759
02/28/2024 2 20.4 96.1 4 98.6 20.2 97.5 95 D6938 Pass
Location : Lot #24, Elv/Depth :8 inches below finished grade
Comment : Gauge Serial No. :85759
02/28/2024 3 26.1 91.8 5 93.8 20.9 97.9 95 D6938 Pass
Location : Lot #23, Elv/Depth :finished grade
Comment : Moisture content exceeds 3 percent over optimum moisture content Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 28, 2024
Reviewer Name / DateKenneth Mosman, March 16, 2024