- Home
- Density Test Report Report ID: 64323
- This project is inactive from admin.Download Report
Density Test Report
Date :02/21/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :02/21/2024 15:00
Onsite Hours :02:30
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :02/21/2024 17:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
02/21/2024 | 1 | 16.8 | 102.2 | 24209 | 111.6 | 16.5 | 91.6 | 90 | D6938 | Pass |
Location : | 35 feet NE of MH A7, Elv/Depth :1.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
02/21/2024 | 2 | 16.6 | 104.7 | 24209 | 111.6 | 16.5 | 93.8 | 90 | D6938 | Pass |
Location : | 53 feet SW of MH A8, Elv/Depth :1 foot below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, February 21, 2024
Reviewer Name / DateKenneth Mosman, March 15, 2024