Density Test Report

Date :02/01/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :02/01/2024 9:30
Onsite Hours :03:30
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :02/01/2024 13:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/01/2024 1 18 101.7 24468 111.3 17.5 91.4 90 D6938 Pass
Location : Creek crossing (location shown in pictures), Elv/Depth :11 feet below finished grade
Comment : Gauge Serial No. :85759
02/01/2024 2 15.5 103.6 24468 111.3 17.5 93.1 90 D6938 Pass
Location : Creek crossing (location shown in pictures), Elv/Depth :10 feet below finished grade
Comment : Gauge Serial No. :85759
02/01/2024 3 15.8 104.7 24468 111.3 17.5 94.1 90 D6938 Pass
Location : Creek crossing (location shown pictures), Elv/Depth :12 feet below finished grade
Comment : Gauge Serial No. :85759
02/01/2024 4 17.6 105.0 24468 111.3 17.5 94.3 90 D6938 Pass
Location : Sewer line 42 feet south of MH A10, Elv/Depth :5 feet below finished grade
Comment : Gauge Serial No. :85759
02/01/2024 5 20.6 101.0 24468 111.3 17.5 90.7 90 D6938 Pass
Location : Storm line 45 feet north of MH A9, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, February 1, 2024
Reviewer Name / DateKenneth Mosman, March 10, 2024