- Home
- Density Test Report Report ID: 63620
- This project is inactive from admin.Download Report
Density Test Report
Date :01/04/2024
Project No :2023C141
Client Company :Toll Bros
Arrival Time :01/04/2024 9:00
Onsite Hours :03:30
Name of the Project :N. Gate - Old Atlanta Road
Project Location :Cumming
Weather :sunny
Departure Time :01/04/2024 12:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
01/04/2024 | 1 | 19 | 126.5 | 24468 | 111.3 | 17.5 | 95.5 | 95 | D6938 | Pass |
Location : | at Lot #32, Elv/Depth :8 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
01/04/2024 | 2 | 18.7 | 104.3 | 24468 | 111.3 | 17.5 | 93.7 | 90 | D6938 | Pass |
Location : | Sewer line, 31 feet SE of MH B4,, Elv/Depth :4.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
01/04/2024 | 3 | 18.5 | 104.4 | 24468 | 111.3 | 17.5 | 93.8 | 90 | D6938 | Pass |
Location : | 32 feet NW of MH B5,, Elv/Depth :5.5 feet below finished grade | |||||||||
Comment : | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, January 4, 2024
Reviewer Name / DateKenneth Mosman, March 10, 2024