Skip to content

Density Test Report

Date :08/24/2023
Project No :2022C227
Client Company :Artisan
Arrival Time :08/24/2023 15:00
Onsite Hours :02:00
Name of the Project :Riverwalk Manor (CMT) Unit 2, PH 4E and 4F
Project Location :Dallas
Weather :sunny
Departure Time :08/24/2023 17:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/24/2023 1 15.3 110.3 P-01 100.4 18.6 95.3 95 D6938 Pass
Location : 112 feet to NW of MH 23., Elv/Depth :1.5 feet below finish grade
Comment : Gauge Serial No. :85759
08/24/2023 2 13.3 95.4 P-01 100.4 18.6 95.0 95 D6938 Fail
Location : 23 feet to NW of MH 23,, Elv/Depth :1.5 feet below finish grade
Comment : the moisture content was low than specified range limit. Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, August 24, 2023
Reviewer Name / DateRamchandra Mogulla, September 14, 2023