- Home
- Density Test Report Report ID: 61044
- Edit Download Report
Density Test Report
Date :08/24/2023
Project No :2022C227
Client Company :Artisan
Arrival Time :08/24/2023 15:00
Onsite Hours :02:00
Name of the Project :Riverwalk Manor (CMT) Unit 2, PH 4E and 4F
Project Location :Dallas
Weather :sunny
Departure Time :08/24/2023 17:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
08/24/2023 | 1 | 15.3 | 110.3 | P-01 | 100.4 | 18.6 | 95.3 | 95 | D6938 | Pass |
Location : | 112 feet to NW of MH 23., Elv/Depth :1.5 feet below finish grade | |||||||||
Comment : | Gauge Serial No. :85759 | |||||||||
08/24/2023 | 2 | 13.3 | 95.4 | P-01 | 100.4 | 18.6 | 95.0 | 95 | D6938 | Fail |
Location : | 23 feet to NW of MH 23,, Elv/Depth :1.5 feet below finish grade | |||||||||
Comment : | the moisture content was low than specified range limit. | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, August 24, 2023
Reviewer Name / DateRamchandra Mogulla, September 14, 2023