Density Test Report

Date :05/17/2023
Project No :2022C113
Client Company :CWM
Arrival Time :05/17/2023 10:00
Onsite Hours :08:00
Name of the Project :Airfield Sewer Enhancements
Project Location :HJAIA
Weather :cloudy
Departure Time :05/17/2023 18:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
05/17/2023 1 3.3 134.8 GAB 23411 140.2 5.7 96.1 90 D6938 Pass
Location : 40 feet to west of MH1, Elv/Depth :- 1.5 foot
Comment : Test result standby for proctor Gauge Serial No. :85759
05/17/2023 2 3.5 134.8 GAB 23411 140.2 5.7 96.1 90 D6938 Pass
Location : 39 feet to west of MH2, Elv/Depth :8 inches below finish grade
Comment : test result standby for proctor Gauge Serial No. :85759
05/17/2023 3 4.5 136.9 GAB 23411 140.2 5.7 97.6 90 D6938 Pass
Location : 17 feet to west of MH1, Elv/Depth :at finish grade
Comment : test result on standby for proctor Gauge Serial No. :85759
05/17/2023 4 5.9 124.9 GAB 23411 140.2 5.7 89.1 90 D6938 Fail
Location : 45 feet to North of MH2, Elv/Depth :1 foot below finish grade
Comment : test result on standby for proctor Gauge Serial No. :85759
05/17/2023 5 6.6 122.6 Recycled GAB 134.9 8.7 90.9 90 D6938 Pass
Location : 25 feet to South of MH3, Elv/Depth :1 foot below finish grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, May 17, 2023
Reviewer Name / DateRamchandra Mogulla, July 10, 2023