- Home
- Density Test Report Report ID: 59269
- This project is inactive from admin.Download Report
Density Test Report
Date :05/11/2023
Project No :2022C113
Client Company :CWM
Arrival Time :05/11/2023 14:30
Onsite Hours :03:30
Name of the Project :Airfield Sewer Enhancements
Project Location :HJAIA
Weather :cloudy
Departure Time :05/11/2023 18:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
05/11/2023 | 1 | 4.1 | 127.8 | Recycled GAB | 134.9 | 8.7 | 94.7 | 90 | D6938 | Pass |
Location : | 40 feet to North of MH#2, Elv/Depth :1.5 feet below finish grade | |||||||||
Comment : | test result is on standby until receive proctor from lab | Gauge Serial No. :85759 | ||||||||
05/11/2023 | 2 | 2.8 | 128.4 | Recycled GAB | 134.9 | 8.7 | 95.2 | 90 | D6938 | Pass |
Location : | 100 feet to South of MH3, Elv/Depth :1.5 feet below finish grade | |||||||||
Comment : | test result is on standby until receive proctor from lab | Gauge Serial No. :85759 |
Technician Signature / DateAminullah Azimi, May 11, 2023
Reviewer Name / DateRamchandra Mogulla, July 10, 2023