Skip to content

Density Test Report

Date :04/24/2023
Project No :2022C235
Client Company :Jackson Demolition Service, Inc.
Arrival Time :04/24/2023 05:40
Onsite Hours :10:15
Name of the Project :Plant Gorgas Demolition and Grading
Project Location :460 Gorgas Rd, Parrish, AL 35580
Weather :Partly Cloudy
Departure Time :04/24/2023 16:00
ASEC Technician Name :Vidal Dias

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/24/2023 1 12.5 115.3 ASEC-1 116.4 16.2 99.1 90 D6938 Pass
Location : Section 1, Elv/Depth :250
Comment : Gauge Serial No. :3430
04/24/2023 2 16.2 108.5 ASEC-2 110.9 15.3 97.8 90 D6938 Pass
Location : Section 2 Sixty feet west of baker's creek wall , Elv/Depth :248
Comment : Gauge Serial No. :30942
04/24/2023 3 14.5 112.8 ASEC-1 116.4 16.2 96.9 90 D6938 Pass
Location : Section 2, Elv/Depth :248
Comment : Gauge Serial No. :30942
Technician Signature / DateVidal Dias, April 24, 2023
Reviewer Name / DateRamchandra Mogulla, April 24, 2023