- Home
- Daily Field Report Report ID: 57234
- Edit Download Report
Daily Field Report
Observations/Finding
Our AS Engineering and Consulting, LLC representative has completed an engineering evaluation of the slab and perimeter footings at Suncity Lot #46 pod 15 and Lot #54 pod 17 residential unit. The footing evaluation was performed by visual inspection, hand probing, and dynamic cone penetrometer (DCP) testing. During the evaluation, well compacted fill soils were encountered underlain by residual soils.
These soils were found to be capable of an allowable soil bearing pressure of 2,000 psf.
Reinforcing steel for footings and slab were visually inspected and appeared to be in accordance with approved project specifications for size, spacing and quantity. During our evaluation it was noted the welded wire mesh was adequately overlapped, vapor barrier was installed and taped as needed, rebar standees were used as needed to provide cover and the rebar appeared to have adequate lap length for its size.
AS Engineering and Consulting, LLC. Appreciates the opportunity to be of service to you on this project. If you have any questions regarding this letter, please contact us.
Lot 46 pod 15
Lot 54 pod 17