Skip to content

Density Test Report

Date :01/16/2023
Project No :2021C002
Client Company :CW Matthews
Arrival Time :01/16/2023 9:30
Onsite Hours :07:00
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :cloudy
Departure Time :01/16/2023 16:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/16/2023 1 21.4 100.5 12 119.8 12.3 83.9 95 D6938 Fail
Location : 30' to the east of MH F1.1, Elv/Depth :-2' from finished grade
Comment : In-situ moisture contents far below optimum moisture contents. Gauge Serial No. :85759
01/16/2023 2 18.4 109.5 12 119.8 12.3 91.4 95 D6938 Fail
Location : 64' to the east of MH F1.1, Elv/Depth :-2 from finished grade
Comment : In-situ moisture contents far below optimum moisture contents. Gauge Serial No. :85759
01/16/2023 3 3.7 116.0 9 120.8 11.3 96.0 95 D6938 Pass
Location : 26' to the west of MH F1.1, Elv/Depth :-1.5 from finished grade
Comment : Gauge Serial No. :85759
01/16/2023 4 4.2 117.0 9 120.8 11.3 96.9 95 D6938 Pass
Location : -15' to the east of MH F1.1, Elv/Depth :-1.5 from finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, January 16, 2023
Reviewer Name / DateKenneth Mosman, January 22, 2023