Skip to content

Density Test Report

Date :11/03/2022
Project No :2022C135
Client Company :Mark Spain
Arrival Time :11/03/2022 11:00
Onsite Hours :07:00
Name of the Project : Barnett Shoals Road Development
Project Location :Watkinsville
Weather :Sunny
Departure Time :11/03/2022 18:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/03/2022 1 23.7 98.5 P-2 99.5 22.1 99.0 95 D6938 Pass
Location : within dam keyway, Elv/Depth :-7.5' from top of keyway
Comment : Gauge Serial No. :29588
11/03/2022 2 23.7 99.6 P-2 99.5 22.1 100.1 95 D6938 Pass
Location : within dam keyway, Elv/Depth :-7.5' from keyway
Comment : Gauge Serial No. :29588
11/03/2022 3 22.2 98.0 P-2 99.5 22.1 98.5 95 D6938 Pass
Location : in the south of keyway, Elv/Depth :-8' from top of keyway
Comment : Gauge Serial No. :29588
11/03/2022 4 24.3 100.6 P-2 99.5 22.1 101.1 95 D6938 Pass
Location : in the south of keyway, Elv/Depth :-7.5' from top of keyway
Comment : Gauge Serial No. :29588
11/03/2022 5 22.3 98.0 P-2 99.5 22.1 98.5 95 D6938 Pass
Location : in the south of keyway, Elv/Depth :-7.5' from top of keyway
Comment : Gauge Serial No. :29588
11/03/2022 6 23.4 99.4 P-2 99.5 22.1 99.9 95 D6938 Pass
Location : in the north of keyway , Elv/Depth :-7.5' from top of keyway
Comment : Gauge Serial No. :29588
Technician Signature / DateAminullah Azimi, November 3, 2022
Reviewer Name / DateKenneth Mosman, November 13, 2022