- Home
- Density Test Report Report ID: 54611
- This project is inactive from admin.Download Report
Density Test Report
Date :09/08/2022
Project No :2022C128
Client Company :Century
Arrival Time :09/08/2022 11:00
Onsite Hours :03:30
Name of the Project :Sidney Square, Flowery Branch
Project Location :Flowery Branch
Weather :Cloudy
Departure Time :09/08/2022 14:30
ASEC Technician Name :Vidal Dias
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/08/2022 | Test 1 | 27.9 | 90.2 | 2 | 92.8 | 22.3 | 97.2 | 98 | D6938 | Fail |
Location : | Final grade of first section , Elv/Depth : | |||||||||
Comment : | Gauge Serial No. : | |||||||||
09/08/2022 | Test 2 | 23.8 | 93.1 | 2 | 92.8 | 22.3 | 100.3 | 98 | D6938 | Pass |
Location : | Final grade of first section , Elv/Depth : | |||||||||
Comment : | Gauge Serial No. : | |||||||||
09/08/2022 | test 3 | 17.8 | 100.7 | 2 | 92.8 | 22.3 | 108.5 | 95 | D6938 | Pass |
Location : | Lift one of second section , Elv/Depth : | |||||||||
Comment : | Gauge Serial No. : |
Technician Signature / DateVidal Dias, September 8, 2022
Reviewer Name / DateKenneth Mosman, October 23, 2022