Daily Field Report

Date :04/08/2022
Project No :2020C007
Client Company :Pulte Group
Arrival Time :04/08/2022 04:00
Onsite Hours :01:00
Name of the Project :Winslow at Brookstone
Project Location :6156 Collins Road, Acworth, GA 30101
Weather :
Departure Time :04/08/2022 05:00
ASEC Technician Name :Jamal Geathers

Observations/Finding

The site was visited by the undersigned AS Engineering and Consulting (ASEC) representative for the purpose of providing quality control inspection and testing services. Visual observation techniques were employed to assure compliance with project drawings/specifications, applicable codes, and materials submittals. The following observations were made on site today for Lot #43.
 
During the evaluation, unconsolidated soils were encountered underlain by residual soils within the planned building pad area. These soils were found to be insufficient for an allowable soil bearing pressure of 2000 psf. The building pad appears to be unsatisfactory for slab construction. Replacement is required for the North section of the lot. Unsuitable soils should be undercut 6 inches and replaced with graded aggregate base (GAB) and over-poured with concrete or placed back with clean compacted structural fill.
Depth
(feet)
Set
2″
N
1.75″
1 3 5
2 3 6
3 3 8
4 3 7
Technician Signature / DateJamal Geathers, April 8, 2022
Reviewer Name / DateKenneth Mosman, April 24, 2022