- Density Test Report Report ID: 53248
- This project is inactive from admin.Download Report
Density Test Report
Date :03/09/2022
Project No :2021C082
Client Company :CCG Constructors LLC (Century)
Arrival Time :02/16/2022
Onsite Hours :
Name of the Project :Estates at Old Friendship
Project Location :Buford, GA
Weather :40 Cloudy
Departure Time :02/16/2022
ASEC Technician Name :Russell Hendrix
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
02/16/2022 | 1 | 15.5 | 83.9 | P-1 | 109.6 | 15.7 | 76.6 | 95 | D6938 | Fail |
Location : | Proposed road Friendship Creek Drive (Sta 5+00), Elv/Depth :1063 | |||||||||
Comment : | Recompaction necessary | Gauge Serial No. :38069 | ||||||||
02/16/2022 | 2 | 15.3 | 89.7 | P-1 | 109.6 | 15.7 | 81.8 | 95 | D6938 | Fail |
Location : | Friendship Creek Drive (Sta 4+00), Elv/Depth :1063 | |||||||||
Comment : | Recompaction necessary | Gauge Serial No. :38069 | ||||||||
02/16/2022 | 3 | 17.7 | 85.1 | P-1 | 109.6 | 15.7 | 77.6 | 95 | D6938 | Fail |
Location : | Main road (Sta 16+50), Elv/Depth :1081 | |||||||||
Comment : | Recompaction necessary | Gauge Serial No. :38069 | ||||||||
02/16/2022 | 4 | 15.5 | 84.5 | P-1 | 109.6 | 15.7 | 77.1 | 95 | D6938 | Fail |
Location : | Main road (Sta 15+50), Elv/Depth :1081 | |||||||||
Comment : | Recompaction necessary | Gauge Serial No. :38069 |
Technician Signature / DateRussell Hendrix, March 9, 2022
Reviewer Name / DateKenneth Mosman, February 16, 2023