- Home
- Density Test Report Report ID: 34472
- This project is inactive from admin.Download Report
Density Test Report
Date :09/30/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :09/30/2021 16:30
Onsite Hours :02:00
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :09/30/2021 18:30
ASEC Technician Name :Christopher Burrow II
Observations/Finding
Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
---|---|---|---|---|---|---|---|---|---|---|
09/30/2021 | 1 | 16.6 | 101.0 | P-3 | 103.0 | 18.1 | 98.1 | 95 | D6938 | Pass |
Location : | Left center of lot 295, Elv/Depth :3’ below final grade | |||||||||
Comment : | Gauge Serial No. :38069 | |||||||||
09/30/2021 | 2 | 15 | 104.4 | P-3 | 103.0 | 18.1 | 101.4 | 95 | D6938 | Pass |
Location : | Center of cul-de-sac by lot 295, Elv/Depth :3’ below final grade | |||||||||
Comment : | Gauge Serial No. :38069 |
Technician Signature / DateChristopher Burrow II, September 30, 2021
Reviewer Name / DateKenneth Mosman, December 04, 2021