Skip to content

Density Test Report

Date :09/24/2021
Project No :2021C074
Client Company :DR Horton West
Arrival Time :09/24/2021 14:00
Onsite Hours :01:30
Name of the Project :Oakhurst Glen - Ph 4
Project Location :Mallord Drive, South Fulton, GA
Weather :Partly cloudy
Departure Time :09/24/2021 15:30
ASEC Technician Name :Christopher Burrow II

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/24/2021 1 15.7 104.0 P-3 103.0 18.1 101.0 95 D2937 Pass
Location : Center of lot 310, Elv/Depth :2’ below final grade
Comment :
Technician Signature / DateChristopher Burrow II, September 24, 2021
Reviewer Name / DateRamchandra Mogulla, October 13, 2021