Skip to content

Density Test Report

Date :09/07/2021
Project No :2021C070
Client Company :CCG Constructors LLC (Century)
Arrival Time :08/27/2021 09:15
Onsite Hours :04:45
Name of the Project :Harmony Heights
Project Location :Mt. Olive Road at Brentwood Drive, Commerce, GA
Weather :sunny
Departure Time :08/27/2021 14:00
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/27/2021 1 19.8 92.7 P-01 102.0 16.6 90.9 90 D6938 Pass
Location : back of subdivision near detention pond, Elv/Depth :790
Comment : Gauge Serial No. :29588
08/27/2021 2 18.5 92.3 P-01 102.0 16.6 90.5 90 D6938 Pass
Location : back of subdivision near detention pond, Elv/Depth :790
Comment : Gauge Serial No. :29588
08/27/2021 3 21.2 92.7 P-01 102.0 16.6 90.9 90 D6938 Pass
Location : back of subdivision near detention pond, Elv/Depth :790
Comment : Gauge Serial No. :29588
Technician Signature / DateRussell Hendrix, September 7, 2021
Reviewer Name / DateRamchandra Mogulla, November 07, 2021