Skip to content

Density Test Report

Date :11/11/2020
Project No :
Client Company :DR Horton
Arrival Time :11/11/2020 10:00
Onsite Hours :04:00
Name of the Project :Monet Gardens
Project Location :River Road at Green Pastures Way, Ellenwood, GA
Weather :Sunny
Departure Time :11/11/2020 14:00
ASEC Technician Name :Ramchandra Mogulla

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/11/2020 10 16.8 93.4 P-2 102.3 18.0 91.3 90 D2937 Pass
Location : Lot # 9 and vicinity, Elv/Depth :- 7 feet
Comment :
11/11/2020 11 15.8 92.8 P-2 102.3 18.0 90.7 90 D2937 Pass
Location : Lot # 9 and vicinity, Elv/Depth :-6 feet
Comment :
Technician Signature / DateRamchandra Mogulla, November 11, 2020
Reviewer Name / DateKenneth Mosman, December 15, 2021