Skip to content

Density Test Report

Date :11/03/2020
Project No :
Client Company :DR Horton
Arrival Time :11/03/2020 10:00
Onsite Hours :06:00
Name of the Project :Monet Gardens
Project Location :River Road at Green Pastures Way, Ellenwood, GA
Weather :Sunny
Departure Time :11/03/2020 16:00
ASEC Technician Name :Ramchandra Mogulla

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/03/2020 4 16.5 93.2 P-2 102.3 18.0 91.1 90 D2937 Pass
Location : Lot 9, Elv/Depth :-12 feet
Comment :
11/03/2020 5 15.7 94.3 P-2 102.3 18.0 92.2 90 D2937 Pass
Location : Lot 9, Elv/Depth :-10 feet
Comment :
Technician Signature / DateRamchandra Mogulla, November 3, 2020
Reviewer Name / DateKenneth Mosman, December 10, 2021